SPA Location Warning!
The following information is provided for hooking up electrical supply to the spa. This work must be performed by a qualified licensed electrician. Failure to have this done can result in termination of all warranty coverage and also create an extremely dangerous bathing environment.
Recomendations
Your Artesian spa is programmed at the factory to be hooked up in a 240-Volt, high-current configuration, and we recommend that it be hooked up as such. Artesian spas require a 50-amp breaker. Using 4 x 6 AWG wires.
240 volt Installation Procedure
1. The correctly sized GFCI circuit breaker must
be installed at the main electrical service
panel. In addition, a properly suited shut-off switch must also be installed
in plain view of
the spa. This is in compliance with section 422-20 of the National Electrical
Code,
ANSI/NFPA 70-1987. The electrical service panel must be readily accessible
to the spa
occupant but must not be within 5 feet of the spa.
2. After spa has been positioned, route line through knockout on the left
or right front of
spa cabinet.
3. Route line inside cabinet to the hole provided under or behind control
box through hole
provided.
5. Attach wires to the terminal block inside control box. Refer to the
240V wiring diagram
inside the front face plate of the control box and adjacent to terminal
block for final
connection instructions.
6. Complete wire connections at main service panel GFCI breaker.
7. Do not turn power on until instructed to do so in the "SPA START
UP" section.
NOTE: Several bonding lugs are provided
on the control box and other components located inside the equipment compartment
of the spa. Connect a No.8 AWG (8.4mm) solid copper conductor to these
lugs and any metal object within 5 feet (1.5m) of the spa.